Get complete information related to latest Floating Pump Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Floating Pump Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Floating Pump Tenders.
Tender For corrigendum : sitc of agri food bio mug turnkey pilot plant setup d d - process equipment with automation , civil works retrofit , civil external misc. incl , hvac works , hvac controls bms works , metallic insulated panels and cleanroom panel systems design , compressor and drier , electric boiler , thermic fluid heating system , water cooled brine chiller , water cooled chiller , cooling tower , pumps , water ring vacuum pump , chilled water piping for process and hvac , chilled brine piping for process , cooling water generation and distribution piping , compressed air instrument air generation and distribution piping , vacuum distribution , low pressure steam lpst piping distribution , high pressure steam hpst piping distribution , thermic fluid piping distribution , soft water distribution , nitrogen gas distribution , carbon di oxide gas piping distribution , oxygen gas piping distribution , structural steel supports works , equipment erection , drain piping , process piping , process cip piping , electrical lt systems , electrical ht works , fire alarm system , public address system , access control system , door interlocking system , closed circuit televisison cctv , gas detection system , networking voice and data system design , fire protection system , dismantling works
Tender For engg defects rectification - various engineering defects, e-867:03 in nos. fan fire flap stuck in position. same to be made free to rotate for operation from remote and manual. in way job includes removal and fitment of motor fan housing., e-868:performance of ref plant observed sub optimal. di/dr to be carried out and plant to be proved for satisfactory operation. in way job includes pressure testing by nitrogen gas and refrigerant to be charge post vaccum process., e-869:abnormal noise observed from port fin stabilizer hydraulic pump. di/dr to be carried out and fin stabilizer to be proved for satisfactory operation. in way job includes removal and re-fitment of pump in position., e-870:pin hole observed from chilled water expansion tank of ac plant frequently due to aging. same to be fabricated as per sample (mat-ss)..
Tender For a. replacement of existing worn out and obsolete hvac water cooled chiller with new 250 tr water cooled chiller in hospital block at jipmer. b. replacement of existing worn out and obsolete hvac chilled water pump sets, cooling towers and chiller electrical power panel with new ones in the existing hvac plant in hospital block at jipmer.subwork/packages:electrical